The table below lists some of the test equipment that others have used with PrintCapture. If you have used something not listed below we would like to hear from you. We would also like to hear from you if you have used one of the models listed below with a different print mode or if you have additional information that you would like to share. Please send your information to support@printcapture.com.

When looking at the following list of test equipment you will notice that we used the term Hewlett-Packard instead of Agilent. The names are essentially interchangeable. If we mention a Hewlett-Packard 54616C it (probably) also applies to an Agilent 54616C.

PrintCapture 3.x added an I/O interface for National Instruments GPIB interfaces that use National Instruments' NI-488.2 device driver. NI's NI-488.2 device driver and GPIB interface must already be installed and working on your computer before it can be used by PrintCapture. If your computer has a National Instruments GPIB interface you will not need a GPIB-to-serial converter for your test equipment equipped with a GPIB interface.

One of our customers has developed a GPIB-to-USB interface that works well with PrintCapture. You can find out more about this interface at Prologix. Nice little product that works well and is a very good alternative to the pricey National Instruments or Agilent product lines. Its driver makes the USB port look like a serial port on your PC. We have created a PrintCapture-Prologix Setup Document that will hopefully help you configure PrintCapture and Prologix to work together.

Note of Interest: The use of PrintCapture has grown far beyond the initial target of oscilloscopes, logic analyzers, and spectrum analyzers. Customers are now using PrintCapture with many devices that we didn't envision or even know about.

Advantest R3265

No further information.

Advantest R3365

HPGL data format. HPGL data from this unit cannot be processed by PrintCapture. The data contains multiple scaling commands (IP and/or SC commands) that presents a problem for HPGL processing.

Advantest R3465 Modulation Spectrum Analyzer

GPIB and serial interface. HPGL data format. One customer could not get his R3465 to communicate with a B&B Electronics' 2322SPS2 parallel-to-serial converter. He was going to switch to an ATEN parallel-to-serial converter to see if that would fix the problem.

Advantest R3761 Network Analyzer

GPIB interface. HPGL data format.

Advantest R4131D Spectrum Analyzer

GPIB interface. HPGL data format. Use PrintCapture 3.2.21 or later for correct processing of HPGL Character Plot (CP) commands.

Advantest R4136 Spectrum Analyzer

GPIB interface. HPGL data format.

Advantest R9211E

No further information.

Advantest TR9404 Digital Spectrum Analyzer

GPIB interface. HPGL data format.

Anritsu ME538M Microwave System Analyzer

Requires a parallel-to-serial converter. The Anritsu DPR7713A printer setting can be used to transmit Epson command codes.

Anritsu MS2601A Spectrum Analyzer

GPIB and serial interface. PCL data format.

Anritsu MS2601B Spectrum Analyzer

GPIB interface. PCL data format.

Anritsu MS2602A Spectrum Analyzer

GPIB interface. HPGL data format.

Anritsu MS2661A Spectrum Analyzer

GPIB, parallel, and serial interfaces. Epson data format.

Anritsu MS2661C Spectrum Analyzer

GPIB and serial interfaces. HPGL data format.

Anritsu MS2665C Spectrum Analyzer

GPIB and serial interfaces. HPGL, PCL data formats.

Arburg Mold Machine 270S Series 250-150

Serial interface. PCL data formats.

Arburg Mold Machine 320C Series 500-250

Serial interface. PCL data formats.

Audio Precision P1-DD Audio Analyzer

Serial interface. PCL data formats.

Audio Precision Portable One Plus Access

Parallel interface. Epson, PCL data formats. The Japanese company that reported using this instrument uses a parallel-to-USB converter that can be found at this Japanese website: http://www.hdl.co.jp/home.html. Look for the links to "USB-006".

Bruel & Kjar Sound & Vibration Measurement A/S

GPIB interface.

Christy CASP 2000 Battery Conditioning System

Serial interface. Epson data format.

DOS Programs

Epson data format. Several customers have reported using some of their old DOS programs to send Epson data.

Dr. Schulenger Pharmatron Modem 6D Tablet Hardness Tester

Serial interface. Use a straight-through serial cable. Unknown data format, but suspect it is Epson.

Fluke 199 Scope Meter

Epson, PCL data formats. Epson FX/LQ, DeskJet, LaserJet.

Fluke PM97 Scope Meter

Serial interface. Epson data format.

Gigatronics 8501A Peak Power Meter

GPIB interface. HPGL data format.

Gould 450 Digital Storage Oscilloscope

Serial interface.

Gould 4070 Series Digital Storage Oscilloscope

GPIB interface and an RS-423 serial interface. HPGL data format.

Gould 4074 Digital Storage Oscilloscope

GPIB and serial interfaces.

Gould 4084 Digital Storage Oscilloscope

GPIB and serial interfaces.

Hewlett-Packard ESA-L1500A (E4411A) Portable Spectrum Analyzer

GPIB, parallel, and serial interfaces. HPGL, PCL, and Epson data formats.

Hewlett-Packard 1630D Logic Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 1631D Logic Analyzer

GPIB interface. PCL data format.

Hewlett-Packard 1650A Logic Analyzer

Serial interface. Select Alternate printer type on the HP RS-232 configuration menu. Select NONE for handshaking because XON/XOFF handshaking causes lost data. Set PrintCapture to hardware RTS/CTS handshaking. The 1650A prints very slowly so there is little chance of buffer overruns. Set serial parameters to 19200 baud, 8 data bits, 1 stopbit, and no parity. The 1650A is a DCE so it plugs into the PC's DTE serial port using a generic straight-through 9-to-25 pin cable. Thank you, David F.!

Hewlett-Packard 1651 Logic Analyzer

Serial interface.

Hewlett-Packard 1651A 32 Channel Logic Analyzer

GPIB and serial interfaces.

Hewlett-Packard 1651B 32 Channel Logic Analyzer

GPIB and serial interfaces.

Hewlett-Packard 1652B Logic Analyzer

GPIB and serial interfaces. PCL data format.

Hewlett-Packard 1660C Logic Analyzer

Serial interface. PCL data format.

Hewlett-Packard 1661A 102 Channel Portable Logic Analyzer

GPIB and serial interface. PCL, Epson data formats.

Hewlett-Packard 1672D Logic Analyzer

Serial interface. PCL data format.

Hewlett-Packard 3560 Signal Analyzer

Serial interface. HPGL data format.

Hewlett-Packard 3561A

GPIB interface. HPGL data format.

Hewlett-Packard 3562A Dynamic Signal Analyzer

GPIB interface. HPGL data format. You may have to use PrintCapture 3.2.20 or later to properly process the HPGL Output Commands ("Ox").

Hewlett-Packard 3563A Control Systems Analyzer

GPIB interface. HPGL data format. One customer's HP3563A evidently has firmware that still has HPGL debug and development output commands ("OP" and "OE") embedded through-out the HPGL data. PrintCapture can't process the output commands for these HP3563As. He solved his problem by running his HP7470A in parallel (no pens and no paper) with PrintCapture so the HP7470A responds to the commands and allows the HP3563A to send its data to PrintCapture.

Update: PrintCapture 3.2.17 and later should do a better job of processing the HPGL "Ox" output commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 3577A Network Analyzer

GPIB interface. HPGL data format. One customer used a Tastronic TAS001 GPIB-to-serial converter. PrintCapture 3.2.8 now processes the cursor markers.

Hewlett-Packard 3585B Spectrum Analyzer

GPIB interface. HPGL, PCL data format. Customers have reported using National Instruments' GPIB-232CV-A GPIB-to-serial converter in "D" mode. You should review the GPIB-232CV-A configuration FAQ before buying one of these converters.

Hewlett-Packard 3588A Spectrum Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 3589A Spectrum / Network Analyzer

GPIB interface. HPGL, PCL data format. Customers have reported using National Instruments' GPIB-232CV-A GPIB-to-serial converter in "D" mode. You should review the GPIB-232CV-A configuration FAQ before buying one of these converters.

Hewlett-Packard 4145A Parameter Analyzer

GPIB interface.

Hewlett-Packard 4145B Parameter Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 4155A Parameter Analyzer

GPIB and serial interfaces. HPGL, PCL data formats. Evidently HPGL has multiple scaling commands and can't be processed at this time. PCL data is supported. The 4155A has an unusual PCL data format that caused some text data to be overlaid with graphics data. PrintCapture 3.2.14 fixes this problem.

Hewlett-Packard 4194A Impedance / Gain Phase Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 4195A Network / Spectrum Analyzer

GPIB interface. HPGL data format. One of out customers created this HP4195A & PrintCapture Setup.pdf document to help other configure their 4195A to work with PrintCapture. Thank you Gary F. for sharing!

Hewlett-Packard 4395A Network / Spectrum / Impedance Analyzer

GPIB and parallel interfaces. The Japanese company that reported using this instrument uses a parallel-to-USB converter that can be found at this Japanese website: http://www.hdl.co.jp/home.html. Look for the links to "USB-006".

Hewlett-Packard 4396A Network Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 8350 Sweeper

GPIB interface.

Hewlett-Packard 8431B Sweeper

GPIB interface.

Hewlett-Packard 8510 Microwave Vector Network Analyzer (8510B?, 8510C?)

Serial interface. HPGL data format. Use PrintCapture 3.x for best results.

Hewlett-Packard 8510B Network Analyzer

GPIB interface. HPGL data format. Use PrintCapture 3.x for best results. The HPGL data has to be scaled to produce a circular plot instead of an ellipse.

Hewlett-Packard 8510C Network Analyzer

HPGL, PCL data formats. Requires PrintCapture version 2.9.1 or later to process PCL data.

Hewlett-Packard 8512A Reflection / Transmission Test Set

No further information.

Hewlett-Packard 8560A Spectrum Analyzer

Has a GPIB interface. HPGL data format. Customers have reported using National Instruments' GPIB-232CV-A GPIB-to-serial converter. You should review the GPIB-232CV-A configuration FAQ before buying one of these converters.

Hewlett-Packard 8560E Portable Spectrum Analyzer

GPIB interface. HPGL data format. Customers have reported using National Instruments' GPIB-232CV-A GPIB-to-serial converter. You should review the GPIB-232CV-A configuration FAQ before buying one of these converters.

Hewlett-Packard 8561E Portable Spectrum Analyzer

GPIB interface. HPGL data format. Customers have reported using National Instruments' GPIB-232CV-A GPIB-to-serial converter. You should review the GPIB-232CV-A configuration FAQ before buying one of these converters.

Hewlett-Packard 8562A Portable Spectrum Analyzer

GPIB interface. HPGL data format. One customer had all kinds of problems with his GPIB setup and PrintCapture until he realized that the 8562A has predesignated GPIB addresses for its printer (address 1) and plotter (address 5). Be sure you verify PrintCapture's GPIB address if you are having problems.

Hewlett-Packard 8563A Portable Spectrum Analyzer

GPIB interface. HPGL data format. Customers have reported using National Instruments' GPIB-232CV-A GPIB-to-serial converter. You should review the GPIB-232CV-A configuration FAQ before buying one of these converters. Customers have also reported using National Instruments' GPIB-USB-HS.

Hewlett-Packard 8563E Portable Spectrum Analyzer

GPIB interface. HPGL data format. Customers have reported using National Instruments' GPIB-232CV-A GPIB-to-serial converter. You should review the GPIB-232CV-A configuration FAQ before buying one of these converters.

Hewlett-Packard 8563EC Color Portable Spectrum Analyzer

GPIB interface. HPGL data format. The one customer that tried to use this instrument on a GPIB interface had all kinds of problems transferring data. We finally had to give up. Please let us know if you have any information about this instrument and PrintCapture.

Hewlett-Packard 8564E Portable Spectrum Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 8564EC Color Portable Spectrum Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 8565E Portable Spectrum Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 8566B Spectrum Analyzer

GPIB interface. HPGL data format. Requires PrintCapture version 2.8.5 or later. A new control was added to Setup> Configuration> HPGL Processing> Process Output Commands> Process Output Commands that must be checked so PrintCapture responds to a command sent by the HP8566B. Customers have reported using National Instruments' GPIB-232CV-A GPIB-to-serial converter. You should review the GPIB-232CV-A configuration FAQ before buying one of these converters. Others have used National Instruments' GPIB-USB-B interface.

Update: PrintCapture 3.2.17 and later should do a better job of processing the HPGL "Ox" output commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 8568B Spectrum Analyzer

GPIB interface. HPGL data format. Requires PrintCapture version 2.8.5 or later. A new control was added to Setup> Configuration> HPGL Processing> Process Output Commands> Process Output Commands that must be checked so PrintCapture responds to a command sent by the HP8568B. Customers have reported using National Instruments' GPIB-232CV-A and Blackbox's IC026A GPIB-to-serial converters. You should review the GPIB-232CV-A configuration FAQ and the IC026A configuration FAQ before buying one of these converters.

Update: PrintCapture 3.2.17 and later should do a better job of processing the HPGL "Ox" output commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 8569A Spectrum Analyzer

GPIB interface. At least one customer reported that the only way to get his HP8569A to work was to set GPIB address 31 for the plotter address. However, valid GPIB addresses are from 0 through 30, so GPIB address 31 is an illegal address. We never could get this resolved. The net effect is that it appears that PrintCapture won't work with the HP8569A. If you have any further information please let us know.

Hewlett-Packard 8569B Microwave Spectrum Analyzer

GPIB interface. One customer sent a raw data file from the HP8569B that was not HPGL, PCL, or Epson data. The raw data file looked like it was targeted at a specific non-HP plotter but no further information is available. The net effect is that it appears that PrintCapture won't work with the HP8569B. If you have any further information please let us know.

Hewlett-Packard 8590A RF Spectrum Analyzer

HPGL, PCL data formats.

Hewlett-Packard 8590B Spectrum Analyzer

HPGL, PCL data formats.

Hewlett-Packard 8590F Spectrum Analyzer

GPIB interface. HPGL, PCL data formats. At least one customer reported that they had to set PrintCapture's GPIB address to "Listen Only". PrintCapture is not able to process the data when the 8590F is set to send data to a PaintJet. We are researching the PaintJet data to see how we can add PaintJet processing.

Update: PrintCapture 3.2.3 added support for Paintjet (PCL color) data processing.

Hewlett-Packard 8591A Spectrum Analyzer

GPIB interface. HPGL, PCL, Epson data formats.

Hewlett-Packard 8591C Cable TV Analyzer

Serial and parallel interfaces (GPIB and parallel interfaces are optional). PCL data format.

Hewlett-Packard 8591E Spectrum Analyzer

GPIB and serial interfaces. HPGL, PCL, Epson data formats. Requires PrintCapture version 2.8.5 or later. A new control was added to Setup> Configuration> HPGL Processing> Process Output Commands> Process Output Commands that must be checked so PrintCapture responds to a command sent by the HP8591E. Evidently some HP8591Es display 0 (zeros) with a slash through them. PrintCapture 3.0.0 and later properly processes this data.

Update: PrintCapture 3.2.17 and later should do a better job of processing the HPGL "Ox" output commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 8591EM EMI Spectrum Analyzer

HPGL, PCL, Epson data formats.

Hewlett-Packard 8592A Portable Spectrum Analyzer

GPIB interface.

Hewlett-Packard 8592L Portable Spectrum Analyzer

GPIB, serial, and parallel interfaces.

Hewlett-Packard 8593 Spectrum Analyzer. No further information on the model suffix (A, E, EM).

GPIB interface. HPGL data format.

Hewlett-Packard 8593A Spectrum Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 8593EM EMC Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 8594E Spectrum Analyzer

GPIB and serial interfaces. HPGL, PCL data formats. Evidently some HP8594Es display 0 (zeros) with a slash through them. PrintCapture 3.0.0 and later properly processes this data.

Hewlett-Packard 8595E Portable Spectrum Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 8596 Portable Spectrum Analyzer. No further information on the model suffix (E, EM).

GPIB interface. HPGL data format.

Hewlett-Packard 8596EM Portable Spectrum Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 8703B Network Analyzer

GPIB interface. PCL data format.

Hewlett-Packard 8711?

Unknown.

Hewlett-Packard 8712?

Unknown.

Hewlett-Packard 8713?

Unknown.

Hewlett-Packard 8713B RF Economy Scaler Network Analyzer

GPIB, parallel, and serial interfaces. HPGL, PCL, Epson data formats. Also supports PaintJet 3630A color printer.

Hewlett-Packard 8713C RF Economy Network Analyzer

GPIB, parallel, and serial interfaces. HPGL, PCL, Epson data formats. Also supports PaintJet 3630A color printer.

Hewlett-Packard 8714?

Unknown.

Hewlett-Packard 8714B RF Economy Vector Network Analyzer

GPIB, parallel, and serial interfaces. HPGL, PCL, Epson data formats. Also supports PaintJet 3630A color printer.

Hewlett-Packard 8714C RF Economy Network Analyzer

GPIB, parallel, and serial interfaces. HPGL, PCL, Epson data formats. Also supports PaintJet 3630A color printer.

Hewlett-Packard 8714ET RF Economy Network Analyzer

GPIB, parallel, and serial interfaces. HPGL, PCL, Epson data formats.

Hewlett-Packard 8719 Network Analyzer

GPIB interface. HPGL, PCL data formats.

Hewlett-Packard 8720B Network Analyzer

GPIB, parallel, and serial interfaces.

Hewlett-Packard 8720D Microwave Vector Network Analyzer

GPIB, parallel, and serial interfaces. HPGL, PCL data formats.

Hewlett-Packard 8722D Microwave Vector Network Analyzer

GPIB, parallel, and serial interfaces. HPGL data format.

Hewlett-Packard 8732 Pin Modulator (not sure if it's the 8732A or 8732B)

Parallel and serial interfaces. One customer used the Epson output format.

Hewlett-Packard 8751A Response Analyzer

GPIB interface. Epson, PCL data formats. PCL B&W is processed but PCL color is not (yet). PrintCapture version 3.1.3 or later does a better job of processing HPGL data from the 8751A.

Update: PrintCapture 3.2.3 added support for Paintjet (PCL color) data processing.

Hewlett-Packard 8752A RF Network Analyzer

GPIB and parallel interfaces. HPGL, PCL data formats. Use PrintCapture 3.x for best results. We are pretty sure that this unit has HPGL "Ox" output commands in the raw data file. Use PrintCapture 3.2.17 or later for better real-time processing of these commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 8752B RF Network Analyzer

GPIB interface. HPGL, PCL data formats. Use PrintCapture 3.x for best results. We are pretty sure that this unit has HPGL "Ox" output commands in the raw data file. Use PrintCapture 3.2.17 or later for better real-time processing of these commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 8752C RF Network Analyzer

GPIB interface. HPGL, PCL data formats. Use PrintCapture 3.x for best results. Evidently the data for a polar display format has to be scaled to produce a circular plot instead of an ellipse. Also of note: One customer used the 8752C successfully while another customer's 8752C evidently has firmware that still has HPGL debug and development commands ("OS" and "OE") embedded in the HPGL data. PrintCapture can't process the "OS" and "OE" commands for these 8752Cs.

Update: PrintCapture 3.2.17 and later should do a better job of processing the HPGL "Ox" output commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 8753A Vector Network Analyzer

No further information.

Hewlett-Packard 8753B Network Analyzer

GPIB interface. HPGL data format. May require PrintCapture version 3.0.3 or later for HPGL processing.

Update: PrintCapture 3.2.17 and later should do a better job of processing the HPGL "Ox" output commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 8753C Network Analyzer

GPIB interface. PCL Color data format. Customers have reported using National Instruments' GPIB-USB-HS USB interface. Customers have also reported using National Instruments' GPIB-232CV-A GPIB-to-serial converter. You should review the GPIB-232CV-A configuration FAQ before buying one of these converters.

Hewlett-Packard 8753D Network Analyzer

GPIB interface and serial interface. HPGL and PCL data formats. At least one customer has an 8753D that generates HPGL data that can't be processed by PrintCapture. It seems that the customer's 8753D evidently has firmware that still has HPGL debug and development commands ("OS" and "OE") embedded in the HPGL data. PrintCapture can't process the "OS" and "OE" commands for these 8753Ds. Other customers are using their 8753D without problems.

Update: PrintCapture 3.2.17 and above should do a better job of processing the HPGL "Ox" output commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 8753E Vector Network Analyzer

GPIB interface. HPGL, PCL data formats.

Hewlett-Packard 8753ES S-Parameter Network Analyzer

Parallel, serial, and GPIB interfaces. HPGL data formats.

Hewlett-Packard 8753ET Transmission/Reflection Vector Network Analyzer

Parallel, serial, and GPIB interfaces. HPGL data formats.

Hewlett-Packard 8757A Scalar Network Analyzer

GPIB interface. HPGL data format. PrintCapture probably won't process the HPGL data. The one 8757A that we worked with had firmware that appeared to have HPGL debugging commands ("OS" and "OE") left in it.

Update: PrintCapture 3.2.17 and later should do a better job of processing the HPGL "Ox" output commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 8757D Scalar Network Analyzer

GPIB interface.

Hewlett-Packard 8920A RF Communications Test Set

Serial interface. PCL data format.

Hewlett-Packard 8920B RF Communications Test Set

GPIB, parallel, and serial (RJ-11 connector) interfaces.

Hewlett-Packard 8981A Vector Modulation Analyzer

GPIB interface.

Hewlett-Packard 8990A Peak Power Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 16500 Logic Analyzer

Serial interface.

Hewlett-Packard 16500A Logic Analyzer

GPIB and serial interfaces. PCL data format.

Hewlett-Packard 16500B Logic Analyzer

GPIB, serial, and parallel interfaces. HPGL data format.

Hewlett-Packard 35665A 2-Channel Dynamic Signal Analyzer

GPIB, serial, and parallel interfaces. HPGL, PCL data formats.

Hewlett-Packard 35670A FFT Dynamic Signal Analyzer

GPIB, serial, and parallel interfaces. HPGL, PCL data formats.

Hewlett-Packard 53310A Modulation Domain Analyzer

GPIB interface. HPGL data format. One customer used PrintCapture to replace their old ThinkJet printers.

One customer put together this webpage (www.gellerlabs.com/hp53310a.htm) on the HP53310A. You might find the information useful.

Hewlett-Packard 54111D Digitizing Oscilloscope

GPIB interface. HPGL data format.

Hewlett-Packard 54112D Digitizing Oscilloscope

GPIB interface. HPGL data format.

Hewlett-Packard 54201A Digital Oscilloscope

GPIB interface. HPGL data format.

Hewlett-Packard 54501A Digitizing Oscilloscope

GPIB interface. HPGL data format. When connecting to PrintCapture, set the HP54501A to Talk Only and PrintCapture to Listen Only.

Hewlett-Packard 54503A Oscilloscope

It appears that HPGL data from this unit cannot be processed by PrintCapture. The data contains multiple scaling commands (IP and/or SC commands) that presents a problem for HPGL processing. If you have any further information, please let us know. PCL data can be processed by PrintCapture.

Hewlett-Packard 54510A Digitizing Oscilloscope

GPIB interface. HPGL data format.

Hewlett-Packard 54600A Digital Oscilloscope

No further information.

Hewlett-Packard 54601A Digital Oscilloscope

No further information.

Hewlett-Packard 54616C Digital Oscilloscope

Epson, PCL Color data formats.

Hewlett-Packard 54624A Portable Digital Storage Oscilloscope

Parallel and serial interfaces. Epson, PCL data formats.

Hewlett-Packard 54642D Mixed Signal Oscilloscope

GPIB interface. Epson data from this unit is 24-pin head data and requires PrintCapture 2.9.3 and above. Laserjet and Deskjet (PCL) data can be processed by PrintCapture 2.9.0, and above, but it creates an image that looks good visually but doesn't print very well. The LaserJet and DeskJet images will require the use of an image editor to produce a printable image. Also be sure to set the image resolution to about 600 DPI.

Hewlett-Packard 54645D Mixed Signal Oscilloscope

GPIB interface. Epson, Laserjet, and Deskjet data from this unit can now be processed by PrintCapture 3.0.1.

Hewlett-Packard 70004A Color Display Unit

HPGL data requires PrintCapture version 2.7.5 or later. Color PrintJet formats cannot be processed by PrintCapture at this time.

Update: PrintCapture 3.2.3 added support for Paintjet (PCL color) data processing.

Hewlett-Packard 70206A Monochrome Display Unit

HPGL data format requires PrintCapture version 2.7.5 or later.

Hewlett-Packard 71000 Modular Spectrum Analyzer

GPIB interface. HPGL data format.

Hewlett-Packard 87510A Gain-Phase Analyzer

GPIB interface. HPGL data format. The 87510A sends HPGL "Ox" output commands that must be processed in real-time. PrintCapture 3.2.17 and later should do a better job of processing the HPGL "Ox" output commands. See Setup> Configuration> HPGL Processing> Special HPGL Command Processing> Process Output Commands.

Hewlett-Packard 8920B Service Monitor

Serial interface. PCL data format.

Hewlett-Packard 89440A Vector Signal Analyzer

HPGL, PCL data formats.

Hewlett-Packard E5061A ENA-L RF Network Analyzer

Parallel and GPIB interfaces.

Hewlett-Packard E5071A ENA Network Analyzer

Parallel and GPIB interfaces.

Hewlett-Packard E8358A PNA Network Analyzer

Parallel, serial, and GPIB interfaces.

Hitachi VC-6545

HPGL data format. There are problems with this 'scope and PrintCapture. Evidently the VC-6545 inserts carriage-return/line-feeds into the HPGL data stream that PrintCapture can't filter out. And there are multiple HPGL scale commands (IP and/or SC) that PrintCapture can't process yet.

Humphrey Field Analyzer, Humphrey Filed Analyzer II

Parallel interface. PCL data format. These eye examination machines use soft fonts to program Hewlett-Packard LaserJets for output. PrintCapture version 3.2.1 is the first version to process soft fonts for the Humphrey Field Analyzers. You will need a parallel-to-serial converter to get the data into PrintCapture. A B&B Electronics (www.bb-elec.com) 232SPS2 parallel-to-serial converter will work and doesn't require a parallel-to-Centronics cable. An ATEN (www.aten.com) SXP-320A will also work. All ATEN parallel-to-serial converters (SXP-320A, SXP-325A, SXP-500) are available from Provantage (www.provantage.com). The ATEN converters are a little harder to use because you need to find a DB25M-to-Centronics36F parallel cable (DB25 Male-to-Centronics36 Female). These cables are a little harder to find but you might try a search on the Internet using the keywords "centronics 36F gender".

IDEXX Blood Analyzer for Veterinery Medicine (includes VetTest 8008 for blood chemistries and QBC machine for red and white count)

Parallel interface. Epson, PCL data formats.

Iwatsu SL-4122 Logic Analyzer

Parallel interface. Epson.

LeCroy 960 WavePro Oscilloscope

GPIB, serial, and parallel interfaces. No further information available.

LeCroy 9300 Series Oscilloscope

GPIB, serial, and parallel, interfaces. No further information available.

LeCroy 9450A Digital Storage Oscilloscope

HPGL, PCL, Epson data formats.

LeCroy LC334A Digital Oscilloscope

Epson B/W, HPGL, DeskJet Color, DeskJet B/W, LaserJet, PaintJet, ThinkJet data formats.

LeCroy Scope Station 140

Epson MX/FX, HP74xx Plotter data formats.

Lindos Audio Measurement Set

Serial interface. PCL data format.

Link Instruments DSO-2102

HPGL data format.
Windows 95/98 - HP7470A, HP7475A, HP7550A, HP7580A, HP7580B, HP7585A, HP7585B, HP7586B
Windows NT/2K - HP7550 Plus, HP-GL/2.

Marconi 2380 Spectrum Analyzer

GPIB interface. HPGL data format. The data from the Marconi 2380 is not processed correctly. The text and graphics data don't line up correctly. The problem is a variation of the multiple scaling commands that PrintCapture doesn't process yet.

Marconi 2945A Communications Service Monitor

No further information.

Marconi 6203 Measurement Test Set

GPIB interface.

MeasureX Vision Paper Industry Scanner (from Honeywell?)

Serial interface. Epson data format.

Mettler Toledo FP81HT-FP90 Thermal Analyzer

Parallel interface. PCL data format.

Norsonic RTA 830 Real Time Analyzer

Unknown, but it may be Epson.

Ono Sokki CS 350 Dual Channel FFT Analyzer

GPIB interface. HPGL data format.

Plisch FMS100 TV Video/Audio Analyzer

Serial interface. No further information.

Puritan-Bennett Renaissance PFT (Pulmonary Function Test)

Serial interface. Epson data format.

Rinco PCS II Ultrasonic Welding Machine

Serial interface. Unknown output format, but suspect it is Epson.

RiserBond 3200 TDR

Serial interface. Epson data format.

Rohde Schwarz EMI Test Receiver EASI

GPIB interface. HPGL data format.

Rohde Schwarz EMI Test System TS9975

HPGL data format.

Rohde Schwarz ESIB. No further information available.

GPIB interface. HPGL data format.

Rohde Schwarz ESS. No further information available.

GPIB interface. HPGL data format.

Rohde Schwarz FSEM30 Spectrum Analyzer

GPIB interface. HPGL data format.

Rohde Schwarz FSH Spectrum Analyzer

Serial interface. PCL data format.

Rohde Schwarz Radio Communication Service Monitor CMS32/52

Parallel interface. PCL, Epson data formats. Evidently PCL data gives a little better output.

Schmid SZ 340 Sound Program Circuit Analyzer

PCL data format with printer Thinkjet option installed.

Tektronix 370 Curve Tracer

Parallel interface. HPGL data format. Some customers have had problems configuring the Tek 370 to work with PrintCapture. If you're having problems try looking at this Tek370 & PrintCapture Setup.pdf document created by one of our customers. Thank you Gary F. for sharing and Gene N. for verifying the information!

Tektronix 492P Spectrum Analyzer

GPIB interface. HPGL data format.

Tektronix 494AP Spectrum Analyzer

GPIB interface. HPGL data format.

Tektronix 494P Spectrum Analyzer

GPIB interface. HPGL data format.

Tektronix 495P Spectrum Analyzer

GPIB interface. HPGL data format.

Tektronix 496P Spectrum Analyzer

GPIB interface. HPGL data format.

Tektronix 497P Spectrum Analyzer

GPIB interface. HPGL data format.

Tektronix 571 Curve Tracer

Parallel interface. Epson data format.

Tektronix 2021 Arbitrary Waveform Generator

PCL, Epson data formats.

Tektronix 2211 Digital / Analog Oscilloscope

Serial interface. HPGL data format.

Tektronix 2216 Digital / Analog Oscilloscope

Option 12, RS-232C communications. HPGL, Epson, and PCL (LaserJet, Deskjet) data format.

Tektronix 2232 Digital / Analog Oscilloscope

HPGL data format. Option 12, RS-232 communications, requires the parameter switch to be set to 0101000000. Thank you Mike W.!

Tektronix 2252 Digital / Analog Oscilloscope

GPIB and parallel interfaces. Epson data format.

Tektronix 2430A Digital Storage Oscilloscope

GPIB interface. HPGL data format. HPGL processing requires PrintCapture version 3.0.4 or later. There is still a problem processing data from the 2430A. There is an HPGL "UC" command that is used to display "user defined characters" like the "u" used as an abbreviation for microseconds. This command is not processed yet.

Update: PrintCapture 3.1.0 added support for HPGL "UC" command processing.

Tektronix 2710 RF Spectrum Analyzer

GPIB and parallel interfaces. HPGL data format.

Tektronix 2712 Spectrum Analyzer

GPIB and serial interfaces. HPGL, Epson data formats. HPGL processing requires PrintCapture version 3.0.0 or later. Other customers have reported using Epson output for PrintCapture processing.

Tektronix 2715 Spectrum Analyzer

GPIB and serial interfaces. HPGL, Epson data formats. HPGL processing requires PrintCapture version 3.0.0 or later. Other customers have reported using Epson output for PrintCapture processing.

Tektronix 2754P Spectrum Analyzer

GPIB interface.

Tektronix 2755P Spectrum Analyzer

GPIB interface.

Tektronix 2756P Spectrum Analyzer

GPIB interface.

Tektronix 2794 Spectrum Analyzer

GPIB interface.

Tektronix 11801B Digital Sampling Oscilloscope

GPIB interface.

Tektronix TDS 210 Digital Real-Time Oscilloscope

Requires TDS2CMA Communications Extension Module (parallel port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet, LaserJet, PCX (PC Paintbrush mono image) data formats.

Tektronix TDS 220 Digital Real-Time Oscilloscope

Requires TDS2CMA Communications Extension Module (parallel port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet, LaserJet, PCX (PC Paintbrush mono image) data formats.

Tektronix TDS 224 Digital Real-Time Oscilloscope

Requires TDS2CMA Communications Extension Module (parallel port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet, LaserJet, PCX (PC Paintbrush mono image) data formats.

Tektronix TDS 320 Digital Real-Time Oscilloscope

Serial, parallel, and GPIB output ports. BMP, Epson, Thinkjet, Deskjet, Laserjet, PCX (PC Paintbrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 360 Digital Real-Time Oscilloscope

Serial, parallel, and GPIB output ports. BMP, Epson, Thinkjet, Deskjet, Laserjet, PCX (PC Paintbrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 380 Digital Real-Time Oscilloscope

Serial, parallel, and GPIB output ports. BMP, Epson, Thinkjet, Deskjet, Laserjet, PCX (PC Paintbrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 420A Digitizing Oscilloscope

Has a GPIB interface and optional parallel and serial interfaces. BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 430A Digitizing Oscilloscope

Has a GPIB interface and optional parallel and serial interfaces.BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 460 Digitizing Oscilloscope

Has a GPIB interface and optional parallel and serial interfaces. BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 460A Digitizing Oscilloscope

Has a GPIB interface and optional parallel and serial interfaces. BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 540A Digitizing Oscilloscope

BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 540B Digitizing Oscilloscope

BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 640A Digitizing Oscilloscope

BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 694C Digital Storage Oscilloscope

GPIB, serial, and parallel interfaces. BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 754A Digitizing Oscilloscope

GPIB interface. BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 754D Digitizing Oscilloscope

GPIB, serial, and parallel interfaces. BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 784D Digital Phosphor Oscilloscope

GPIB, serial, and parallel interfaces. BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 1002 Digitizing Oscilloscope

Requires TDS2CMAX Communications Extension Module (parallel port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet, LaserJet, PCX (PC Paintbrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 2012 Digitizing Oscilloscope

Requires TDS2CMAX Communications Extension Module (parallel port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet, LaserJet, PCX (PC Paintbrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 2014 Digitizing Oscilloscope

Requires TDS2CMAX Communications Extension Module (parallel port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet, LaserJet, PCX (PC Paintbrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 2022 Digitizing Oscilloscope

Requires TDS2CMAX Communications Extension Module (parallel port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet, LaserJet, PCX (PC Paintbrush mono image), TIFF (Tagged Image File Format) data formats.

Tektronix TDS 3034B Digital Phosphor Oscilloscope

Includes parallel port interface standard. Requires TDS3GV Communications Extension Module for serial port and GPIB interfaces. BMP, Epson, ThinkJet, DeskJet, LaserJet, PCX (PC Paintbrush mono image), TIFF (Tagged Image File Format), HPGL data formats.

Tektronix TDS 3052 Digital Phosphor Oscilloscope

Includes parallel port interface standard. Requires TDS3GM Communications Extension Module for serial port and GPIB interfaces. BMP, Epson, ThinkJet, DeskJet, LaserJet, PCX (PC Paintbrush mono image), TIFF (Tagged Image File Format), HPGL data formats.

Tektronix TS 100 TelScout

Serial interface. Epson data format.

Tektronix VM700 Video Test Set

Serial interface. PCL data format.

Tektronix VM700A Video Test Set

Serial interface. PCL data format.

Tencor P-1 Longscan Profilometer

Serial interface. PCL data format.

Toshiba Injection Molding Machines with V10 and V21 controllers

Serial interface. Epson data format.

VolTech TF2000 Gain/Phase and Harmonic Analyzer

Serial and parallel interfaces. Epson data format.

Wallac Wizard 1480 Gamma Counter

Serial interface. Epson and PCL3 data formats.

Wandel & Goltermann PCM4 PCM Channel Measuring Set

GPIB interface. HPGL data format.

Wandel & Goltermann SNA-1 Network/Spectrum Analyzer

GPIB interface. HPGL data format. Needs GPIB address set to receive on GPIB address 29. HPGL plot needs to be scaled to 500-700.

Yokogawa DL708E Digital Oscilloscope and Recorder

GPIB, serial, and parallel interfaces. BMP, Epson, HPGL, PCL, TIFF (Tagged Image File Format) data formats.

Yokogawa DL1540CL Portable Digital Oscilloscope

GPIB interface. BMP, Epson, HPGL Color Plot, PCL, TIFF (Tagged Image File Format) data formats.

Back To Top