The table below lists some of the test equipment that others have
used with PrintCapture. If you have used something
not listed below we would like to hear from you. We would also
like to hear from you if you have used one of the models listed below
with a different print mode or if you have additional information that
you would like to share. Please send your information to
support@printcapture.com.
When looking at the following list of test equipment you will notice
that we used the term Hewlett-Packard instead of Agilent. The names
are essentially interchangeable. If we mention a Hewlett-Packard
54616C it (probably) also applies to an Agilent 54616C.
One of our customers has developed a GPIB-to-USB interface that works
well with PrintCapture. You can find out more about
this interface at Prologix.
Nice little product that works well and is a very good alternative
to the pricey National
Instruments or Agilent product lines. Its driver makes the USB port
look like a serial port on your PC. We have created a PrintCapture-Prologix
Setup Document that will hopefully help you configure PrintCapture
and Prologix to work together.
Advantest R3261C |
GPIB interface. Unknown output format, but suspect
it is HPGL. |
Advantest R3265 |
No further information. |
Advantest R3365 |
HPGL data format. HPGL data from this unit cannot be processed
by PrintCapture. The data contains multiple scaling
commands (IP and/or SC commands) that presents a problem for HPGL
processing.
Update: PrintCapture 3.2.24 now processes multiple
scaling commands. |
Advantest R3465 Modulation Spectrum Analyzer |
GPIB and serial interface. HPGL data format. One customer
could not get his R3465 to communicate with a B&B Electronics' 2322SPS2
parallel-to-serial converter. He was going to switch to
an ATEN parallel-to-serial converter to see if that would
fix the problem. |
Advantest R3761 Network Analyzer |
GPIB interface. HPGL data format. |
Advantest R3762AH Network Analyzer |
HPGL data format. |
Advantest R3765CG Network Analyzer |
GPIB, serial, parallel interface. HPGL data format. |
Advantest R4131D Spectrum Analyzer |
GPIB interface. HPGL data format. Use PrintCapture 3.2.21
or later for correct processing of HPGL Character Plot
(CP) commands. |
Advantest R4136 Spectrum Analyzer |
GPIB interface. HPGL data format. |
Advantest R9211E |
No further information. |
Advantest TR9404 Digital Spectrum Analyzer |
GPIB interface. HPGL data format. |
|
Anritsu ME538M Microwave System Analyzer |
Requires a parallel-to-serial converter. The Anritsu
DPR7713A printer setting can be used to transmit Epson
command codes. |
Anritsu MS2601A Spectrum Analyzer |
GPIB and serial interface. PCL data format. |
Anritsu MS2601B Spectrum Analyzer |
GPIB interface. PCL data format. |
Anritsu MS2602A Spectrum Analyzer |
GPIB interface. HPGL data format. |
Anritsu MS2661A Spectrum Analyzer |
GPIB, parallel, and serial interfaces. Epson data format. |
Anritsu MS2661C Spectrum Analyzer |
GPIB and serial interfaces. HPGL data format. |
Anritsu MS2665C Spectrum Analyzer |
GPIB and serial interfaces. HPGL, PCL data formats. |
Arburg Mold Machine 270S Series 250-150 |
Serial interface. PCL data formats. |
Arburg Mold Machine 320C Series 500-250 |
Serial interface. PCL data formats. |
Audio Precision P1-DD Audio Analyzer |
Serial interface. PCL data formats. |
Audio Precision Portable One Plus Access |
GPIB and parallel interface. Epson, PCL data formats. A Japanese
company that reported using this instrument uses
a parallel-to-USB converter that can be found at this
Japanese website:
http://www.hdl.co.jp/home.html.
Look for the links to "USB-006". |
Bruel & Kjar Sound & Vibration Measurement A/S |
GPIB interface. |
Christy CASP 2000 Battery Conditioning System |
Serial interface. Epson data format. |
DOS Programs |
Epson data format. Several customers have reported using
some of their old DOS programs to send Epson data. |
Dr. Schulenger Pharmatron Modem 6D Tablet Hardness Tester |
Serial interface. Use a straight-through serial
cable. Unknown data format, but suspect it is Epson. |
Electrolab EF-2 Friability Tester |
Parallel interface. This custoner used a Humandata parallel-to-usb
converter USB-006. This is a Japanese company and as far as I can tell
the USB-006 is available only from their website. |
Fluke 192B Scope Meter |
serial, parallel interfaces. Epson, PCL data formats. Epson FX/LQ,
DeskJet, LaserJet. |
Fluke 199 Scope Meter |
Epson, PCL data formats. Epson FX/LQ, DeskJet, LaserJet. |
Fluke PM97 Scope Meter |
Serial interface. Epson data format. |
Gigatronics 8501A Peak Power Meter |
GPIB interface. HPGL data format. |
Gould 450 Digital Storage Oscilloscope |
Serial interface. |
Gould 4070 Series Digital Storage Oscilloscope |
GPIB interface and an RS-423 serial interface. HPGL data
format. |
Gould 4074 Digital Storage Oscilloscope |
GPIB and serial interfaces. |
Gould 4084 Digital Storage Oscilloscope |
GPIB and serial interfaces. |
Hewlett-Packard ESA-L1500A (E4411A) Portable Spectrum Analyzer |
GPIB, parallel, and serial interfaces. HPGL, PCL,
and Epson data formats. |
Hewlett-Packard 1630D Logic Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 1631D Logic Analyzer |
GPIB interface. PCL data format. |
Hewlett-Packard 1650A Logic Analyzer |
Serial interface. Select Alternate
printer type on the HP RS-232 configuration menu. Select
NONE for handshaking because XON/XOFF handshaking causes
lost data. Set PrintCapture to hardware RTS/CTS
handshaking. The 1650A prints very slowly so there is little
chance of buffer overruns. Set serial parameters to 19200 baud, 8
data bits, 1 stopbit, and no parity. The 1650A is a DCE
so it plugs into the PC's DTE serial port using a generic
straight-through 9-to-25 pin cable. Thank you,
David F.! |
Hewlett-Packard 1651 Logic Analyzer |
Serial interface. |
Hewlett-Packard 1651A 32 Channel Logic Analyzer |
GPIB and serial interfaces. |
Hewlett-Packard 1651B 32 Channel Logic Analyzer |
GPIB and serial interfaces. |
Hewlett-Packard 1652B Logic Analyzer |
GPIB and serial interfaces. PCL data format. |
Hewlett-Packard 1660C Logic Analyzer |
Serial interface. PCL data format. |
Hewlett-Packard 1661A 102 Channel Portable Logic Analyzer |
GPIB and serial interface. PCL, Epson data formats. |
Hewlett-Packard 1661AS Logic Analyzer |
GPIB interface. HPGL, PCL data formats. |
Hewlett-Packard 1672D Logic Analyzer |
Serial interface. PCL data format. |
Hewlett-Packard 3040A Network Analyzer |
No further information. |
Hewlett-Packard 3560 Signal Analyzer |
Serial interface. HPGL data format. |
Hewlett-Packard 3561A |
GPIB interface. HPGL data format. |
Hewlett-Packard 3562A Dynamic Signal Analyzer |
GPIB interface. HPGL data format. You may have to use PrintCapture 3.2.20
or later to properly process the HPGL Output Commands ("Ox"). |
Hewlett-Packard 3563A Control Systems Analyzer |
GPIB interface. HPGL data format. One customer's HP3563A
evidently has firmware that still has HPGL debug and development
output commands ("OP" and "OE")
embedded through-out the HPGL data. PrintCapture can't
process the output commands for these HP3563As. He solved
his problem by running his HP7470A in parallel (no pens
and no paper) with PrintCapture so the
HP7470A responds to the commands and allows the HP3563A
to send its data to PrintCapture.
Update: PrintCapture 3.2.17 and later
should do a better job of processing the HPGL "Ox" output
commands. See Setup> Configuration> HPGL Processing> Special
HPGL Command Processing> Process Output Commands. |
Hewlett-Packard 3577A Network Analyzer |
GPIB interface. HPGL data format. One customer used a Tastronic
TAS001 GPIB-to-serial converter. PrintCapture 3.2.8
now processes the cursor markers. |
Hewlett-Packard 3585A Spectrum Analyzer |
GPIB interface. HPGL, PCL data format. |
Hewlett-Packard 3585B Spectrum Analyzer |
GPIB interface. HPGL, PCL data format. Customers have
reported using National Instruments' GPIB-232CV-A GPIB-to-serial
converter in "D" mode. You should review the
GPIB-232CV-A configuration FAQ
before buying one of these converters. |
Hewlett-Packard 3588A Spectrum Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 3589A Spectrum / Network Analyzer |
GPIB interface. HPGL, PCL data format. Customers
have reported using National Instruments' GPIB-232CV-A GPIB-to-serial
converter in "D" mode. You should review the
GPIB-232CV-A configuration FAQ
before buying one of these converters. |
Hewlett-Packard 4145A Parameter Analyzer |
GPIB interface. |
Hewlett-Packard 4145B Parameter Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 4155A Parameter Analyzer |
GPIB and serial interfaces. HPGL, PCL data formats. Evidently
HPGL has multiple scaling commands and can't be processed
at this time. PCL data is supported. The 4155A has an unusual
PCL data format that caused some text data to be overlaid with
graphics data. PrintCapture 3.2.14 fixes this problem.
Update: PrintCapture 3.2.24 now processes
multiple scaling commands. |
Hewlett-Packard 4194A Impedance / Gain Phase Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 4195A Network / Spectrum Analyzer |
GPIB interface. HPGL data format. One of out customers
created this
HP4195A & PrintCapture
Setup.pdf document to help others configure their 4195A
to work with PrintCapture. Thank you Gary F. for sharing! |
Hewlett-Packard 4395A Network / Spectrum / Impedance Analyzer |
GPIB and parallel interfaces. The Japanese
company that reported using this instrument uses a parallel-to-USB
converter that can be found at this Japanese website:
http://www.hdl.co.jp/home.html.
Look for the links to "USB-006". |
Hewlett-Packard 4396A Network Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 8350 Sweeper |
GPIB interface. |
Hewlett-Packard 8431B Sweeper |
GPIB interface. |
Hewlett-Packard 8510 Microwave Vector Network Analyzer
(8510B?, 8510C?) |
Serial interface. HPGL data format. Use PrintCapture 3.x
for best results. |
Hewlett-Packard 8510B Network Analyzer |
GPIB interface. HPGL data format. Use PrintCapture 3.x
for best results. The HPGL data may have to be scaled to produce a
circular plot instead of an ellipse. |
Hewlett-Packard 8510C Network Analyzer |
HPGL, PCL data formats. Requires PrintCapture version
2.9.1 or later to process PCL data. |
Hewlett-Packard 8512A Reflection / Transmission Test Set |
No further information. |
Hewlett-Packard 8530A Network Analyzer (Upgraded from an 8510) |
GPIB interface. HPGL data format. |
Hewlett-Packard 8546A EMI Test Receiver |
GPIB interface. No further information. |
Hewlett-Packard 8560A Spectrum Analyzer |
GPIB interface. HPGL data format. Customers have
reported using National Instruments' GPIB-232CV-A GPIB-to-serial
converter. You should review the GPIB-232CV-A
configuration FAQ before buying one of these converters. |
Hewlett-Packard 8560E Portable Spectrum Analyzer |
GPIB interface. HPGL data format. Customers have reported
using National Instruments' GPIB-232CV-A GPIB-to-serial
converter.
You should review the GPIB-232CV-A
configuration FAQ before buying one of these converters. |
Hewlett-Packard 8561B Spectrum Analyzer |
GPIB interface. PCL Data format. |
Hewlett-Packard 8561E Portable Spectrum Analyzer |
GPIB interface. HPGL data format. Customers have reported
using National Instruments' GPIB-232CV-A GPIB-to-serial
converter.
You should review the GPIB-232CV-A
configuration FAQ before buying one of these converters.
Customers have also reported using the Prologix GPIB-to-USB
Converter 6.0. |
Hewlett-Packard 8562A Portable Spectrum Analyzer |
GPIB interface. HPGL data format. One customer had all
kinds of problems with his GPIB setup and PrintCapture until
he realized that the 8562A has predesignated GPIB addresses
for its printer (address 1) and plotter (address 5). Be
sure you verify PrintCapture's GPIB address
if you are having problems. |
Hewlett-Packard 8563A Portable Spectrum Analyzer |
GPIB interface. HPGL data format. Customers have reported
using National Instruments' GPIB-232CV-A GPIB-to-serial
converter.
You should review the GPIB-232CV-A
configuration FAQ before buying one of these converters.
Customers have also reported using National Instruments'
GPIB-USB-HS. |
Hewlett-Packard 8563E Portable Spectrum Analyzer |
GPIB interface. HPGL data format. Customers have reported
using National Instruments' GPIB-232CV-A GPIB-to-serial
converter. You should review the GPIB-232CV-A
configuration FAQ before buying one of these converters. |
Hewlett-Packard 8563EC Color Portable Spectrum Analyzer |
GPIB interface. HPGL data format. The one customer that
tried to use this instrument on a GPIB interface had all
kinds of problems transferring data. We finally had to give
up. Please let us know if you have any information about this
instrument and PrintCapture. |
Hewlett-Packard 8564E Portable Spectrum Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 8564EC Color Portable Spectrum Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 8565E Portable Spectrum Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 8566B Spectrum Analyzer |
GPIB interface. HPGL data format. Requires PrintCapture version
2.8.5 or later. A new control was added to Setup> Configuration>
HPGL Processing> Process Output Commands> Process
Output Commands that must be checked so PrintCapture
responds to a command sent by the HP8566B. Customers have
reported using National Instruments' GPIB-232CV-A GPIB-to-serial
converter. You should review the
GPIB-232CV-A configuration FAQ before
buying one of these converters. Others have used National
Instruments' GPIB-USB-B interface.
Update: PrintCapture 3.2.17 and later
should do a better job of processing the HPGL "Ox" output
commands. See Setup> Configuration> HPGL Processing> Special
HPGL Command Processing> Process Output Commands. |
Hewlett-Packard 8568B Spectrum Analyzer |
GPIB interface. HPGL data format. Requires PrintCapture version
2.8.5 or later. A new control was added to Setup> Configuration>
HPGL Processing> Process Output Commands> Process
Output Commands that must be checked so PrintCapture responds
to a command sent by the HP8568B. Customers have reported
using National Instruments' GPIB-232CV-A and Blackbox's
IC026A GPIB-to-serial converters. You should review the
GPIB-232CV-A configuration FAQ
and the IC026A configuration FAQ before
buying one of these converters.
Update: PrintCapture 3.2.17 and later
should do a better job of processing the HPGL "Ox" output
commands. See Setup> Configuration> HPGL Processing> Special
HPGL Command Processing> Process Output Commands. |
Hewlett-Packard 8569A Spectrum Analyzer |
GPIB interface. At least one customer reported that
the only way to get his HP8569A to work was to set GPIB
address 31 for the plotter address. However, valid GPIB
addresses are from 0 through 30, so GPIB address
31 is an illegal address. We never could get this
resolved. The net effect is that it appears that
PrintCapture won't work with the HP8569A.
If you have any further information
please let us know. |
Hewlett-Packard 8569B Microwave Spectrum Analyzer |
GPIB interface. One customer sent a raw data file
from the HP8569B that was not HPGL, PCL, or Epson data.
The raw data file looked like it was targeted at a specific
non-HP plotter but no further information is available.
The net effect is that it appears that PrintCapture won't
work with the HP8569B. If you have any further information
please let us know. |
Hewlett-Packard 8590A RF Spectrum Analyzer |
HPGL, PCL data formats. |
Hewlett-Packard 8590B Spectrum Analyzer |
HPGL, PCL data formats. |
Hewlett-Packard 8590F Spectrum Analyzer |
GPIB interface. HPGL, PCL data formats. At least one customer
reported that they had to set PrintCapture's GPIB
address to "Listen Only". PrintCapture is
not able to process the data when the 8590F is set to send
data to a PaintJet. We are researching the PaintJet data to see
how we can add PaintJet processing.
Update: PrintCapture 3.2.3 added support
for Paintjet (PCL color) data processing. |
Hewlett-Packard 8590L Spectrum Analyzer |
GPIB, parallel, and serial interfaces. HPGL, PCL data formats. |
Hewlett-Packard 8591A Spectrum Analyzer |
GPIB interface. HPGL, PCL, Epson data formats. |
Hewlett-Packard 8591C Cable TV Analyzer |
Serial and parallel interfaces (GPIB and parallel interfaces
are optional). PCL data format. |
Hewlett-Packard 8591E Spectrum Analyzer |
GPIB and serial interfaces. HPGL, PCL, Epson data formats.
Requires PrintCapture version
2.8.5 or later. A new control was added to Setup> Configuration> HPGL
Processing> Process Output Commands> Process Output
Commands that must be checked so PrintCapture responds
to a command sent by the HP8591E. Evidently some HP8591Es
display 0 (zeros) with a slash through them.
PrintCapture 3.0.0 and later properly processes this data.
Update: PrintCapture 3.2.17 and later
should do a better job of processing the HPGL "Ox" output
commands. See Setup> Configuration> HPGL Processing> Special
HPGL Command Processing> Process Output Commands. |
Hewlett-Packard 8591EM EMI Spectrum Analyzer |
HPGL, PCL, Epson data formats. |
Hewlett-Packard 8592A Portable Spectrum Analyzer |
GPIB interface. |
Hewlett-Packard 8592L Portable Spectrum Analyzer |
GPIB, serial, and parallel interfaces. |
Hewlett-Packard 8593 Spectrum Analyzer. No further information
on the model suffix (A, E, EM). |
GPIB interface. HPGL data format. |
Hewlett-Packard 8593A Spectrum Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 8593EM EMC Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 8594E Spectrum Analyzer |
GPIB and serial interfaces. HPGL, PCL data formats.
Evidently some HP8594Es display 0 (zeros) with a slash through
them. PrintCapture 3.0.0
and later properly processes this data. |
Hewlett-Packard 8595E Portable Spectrum Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 8596 Portable Spectrum Analyzer. No further
information on the model suffix (E, EM). |
GPIB interface. HPGL data format. |
Hewlett-Packard 8596EM Portable Spectrum Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 8703B Network Analyzer |
GPIB interface. PCL data format. |
Hewlett-Packard 8711? |
Unknown. |
Hewlett-Packard 8712? |
Unknown. |
Hewlett-Packard 8713? |
Unknown. |
Hewlett-Packard 8713B RF Economy Scaler Network Analyzer |
GPIB, parallel, and serial interfaces.
HPGL, PCL, Epson data formats. Also supports PaintJet 3630A
color printer. |
Hewlett-Packard 8713C RF Economy Network Analyzer |
GPIB, parallel, and serial interfaces.
HPGL, PCL, Epson data formats. Also supports PaintJet 3630A
color printer. |
Hewlett-Packard 8714? |
Unknown. |
Hewlett-Packard 8714B RF Economy Vector Network Analyzer |
GPIB, parallel, and serial interfaces.
HPGL, PCL, Epson data formats. Also supports PaintJet 3630A
color printer. |
Hewlett-Packard 8714C RF Economy Network Analyzer |
GPIB, parallel, and serial interfaces.
HPGL, PCL, Epson data formats. Also supports PaintJet 3630A
color printer. |
Hewlett-Packard 8714ET RF Economy Network Analyzer |
GPIB, parallel, and serial interfaces. HPGL, PCL,
Epson data formats. |
Hewlett-Packard 8719 Network Analyzer |
GPIB interface. HPGL, PCL data formats. |
Hewlett-Packard 8719D Microwave Vector Network Analyzer |
GPIB, parallel, and seriall interfaces. HPGL, PCL, Epson data formats. |
Hewlett-Packard 8720B Network Analyzer |
GPIB, parallel, and serial interfaces. |
Hewlett-Packard 8720D Microwave Vector Network Analyzer |
GPIB, parallel, and serial interfaces. HPGL, PCL, Epson data formats. |
Hewlett-Packard 8722D Microwave Vector Network Analyzer |
GPIB, parallel, and serial interfaces. HPGL data format. |
Hewlett-Packard 8732 Pin Modulator (not sure if it's the
8732A or 8732B) |
Parallel and serial interfaces. One customer used
the Epson output format. |
Hewlett-Packard 8751A Response Analyzer |
GPIB interface. Epson, PCL data formats. PCL B&W is
processed but PCL color is not (yet). PrintCapture version
3.1.3 or later does a better job of processing HPGL data
from
the 8751A.
Update: PrintCapture 3.2.3 added support
for Paintjet (PCL color) data processing. |
Hewlett-Packard 8752A RF Network Analyzer |
GPIB and parallel interfaces. HPGL, PCL data formats. Use PrintCapture 3.x
for best results. We are pretty sure that this unit has
HPGL "Ox" output commands in the raw data file.
Use PrintCapture 3.2.17 or later for better real-time processing
of these commands. See Setup> Configuration> HPGL
Processing> Special HPGL Command Processing> Process
Output Commands. |
Hewlett-Packard 8752B RF Network Analyzer |
GPIB interface. HPGL, PCL data formats. Use PrintCapture 3.x
for best results. We are pretty sure that this unit has
HPGL "Ox" output commands in the raw data file.
Use PrintCapture 3.2.17 or later for better real-time processing
of these commands. See Setup> Configuration> HPGL
Processing> Special HPGL Command Processing> Process
Output Commands. |
Hewlett-Packard 8752C RF Network Analyzer |
GPIB interface. HPGL, PCL data formats. Use PrintCapture 3.x
for best results. Evidently the data for a polar display
format has to be scaled to produce a circular plot instead
of an ellipse. Also of note: One customer used the 8752C
successfully while another customer's 8752C evidently has
firmware that still has HPGL debug and development commands
("OS" and "OE") embedded in the HPGL
data.
PrintCapture can't process the "OS"
and "OE" commands for these 8752Cs.
Update: PrintCapture 3.2.17 and later
should do a better job of processing the HPGL "Ox" output
commands. See Setup> Configuration> HPGL Processing> Special
HPGL Command Processing> Process Output Commands. |
Hewlett-Packard 8753A Vector Network Analyzer |
GPIB Interface. |
Hewlett-Packard 8753B Network Analyzer |
GPIB interface. HPGL data format. May require PrintCapture version
3.0.3 or later for HPGL processing.
Update: PrintCapture 3.2.17 and later
should do a better job of processing the HPGL "Ox" output
commands. See Setup> Configuration> HPGL Processing> Special
HPGL Command Processing> Process Output Commands. |
Hewlett-Packard 8753C Network Analyzer |
GPIB interface. PCL Color data format. Customers have reported
using National Instruments' GPIB-USB-HS USB interface. Customers
have also reported using National Instruments' GPIB-232CV-A
GPIB-to-serial converter. You should review the
GPIB-232CV-A configuration FAQ before
buying one of these converters. |
Hewlett-Packard 8753D Network Analyzer |
GPIB interface and serial interface. HPGL and PCL data
formats. At least one customer has an 8753D that generates
HPGL data
that
can't be processed by PrintCapture. It seems
that the customer's 8753D evidently has firmware that still
has HPGL debug and development commands ("OS" and
"OE") embedded in the HPGL data.
PrintCapture can't process the "OS"
and "OE" commands for these 8753Ds. Other customers
are using their 8753D without problems.
Update: PrintCapture 3.2.17 and above
should do a better job of processing the HPGL "Ox" output
commands. See Setup> Configuration> HPGL Processing> Special
HPGL Command Processing> Process Output Commands. |
Hewlett-Packard 8753E Vector Network Analyzer |
GPIB interface. HPGL, PCL data formats. |
Hewlett-Packard 8753ES S-Parameter Network Analyzer |
Parallel, serial, and GPIB interfaces. HPGL data format. |
Hewlett-Packard 8753ET Transmission/Reflection Vector Network
Analyzer |
Parallel, serial, and GPIB interfaces. HPGL data format. |
Hewlett-Packard 8756A Scaler Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 8757A Scalar Network Analyzer |
GPIB interface. HPGL data format. PrintCapture probably
won't process the HPGL data. The one 8757A that we worked
with
had firmware that appeared to have HPGL debugging commands
("OS" and "OE") left in it.
Update: PrintCapture 3.2.17 and later
should do a better job of processing the HPGL "Ox" output
commands. See Setup> Configuration> HPGL Processing> Special
HPGL Command Processing> Process Output Commands. |
Hewlett-Packard 8757D Scalar Network Analyzer |
GPIB interface. HPGL. |
Hewlett-Packard 8920A RF Communications Test Set |
Serial interface. PCL data format. |
Hewlett-Packard 8920B RF Communications Test Set |
GPIB, parallel, and serial (RJ-11 connector)
interfaces. |
Hewlett-Packard 8921A High Speed Analog Designer |
GPIB interface. |
Hewlett-Packard 8973A Noise Figure Analyzer |
GPIB, parallel, serial interfacs. PCL data format |
Hewlett-Packard 8981A Vector Modulation Analyzer |
GPIB interface. |
Hewlett-Packard 8990A Peak Power Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 16500 Logic Analyzer |
Serial interface. |
Hewlett-Packard 16500A Logic Analyzer |
GPIB and serial interfaces. PCL data format. |
Hewlett-Packard 16500B Logic Analyzer |
GPIB, serial, and parallel interfaces. HPGL data format. |
Hewlett-Packard 35665A 2-Channel Dynamic Signal Analyzer |
GPIB, serial, and parallel interfaces. HPGL,
PCL data formats. |
Hewlett-Packard 35670A FFT Dynamic Signal Analyzer |
GPIB, serial, and parallel interfaces. HPGL,
PCL data formats. |
Hewlett-Packard 53310A Modulation Domain Analyzer |
GPIB interface. HPGL data format. One customer used PrintCapture to
replace their old ThinkJet printers.
One customer put together this webpage
(www.gellerlabs.com/hp53310a.htm)
on the HP53310A. You might find the information useful. |
Hewlett-Packard 54111D Digitizing Oscilloscope |
GPIB interface. HPGL data format. |
Hewlett-Packard 54112D Digitizing Oscilloscope |
GPIB interface. HPGL data format. |
Hewlett-Packard 54112D Digitizing Oscilloscope |
GPIB interface. HPGL data format. |
Hewlett-Packard 54120A 20GHz Digitizing Oscilloscope |
GPIB interface. No further information. |
Hewlett-Packard 54501A Digitizing Oscilloscope |
GPIB interface. HPGL,PCL data formats. When connecting to PrintCapture,
set the HP54501A to Talk Only and PrintCapture to
Listen Only. |
Hewlett-Packard 54503A Oscilloscope |
It appears that HPGL data from this unit cannot be processed
by PrintCapture. The data contains multiple
scaling commands (IP and/or SC commands) that presents a
problem for HPGL processing. If you have any further
information, please let us know. PCL data can be processed
by PrintCapture.
Update: PrintCapture 3.2.24 now processes
multiple scaling commands. |
Hewlett-Packard 54510A Digitizing Oscilloscope |
GPIB interface. HPGL data format. |
Hewlett-Packard 54542A 4-Channel Digitizing Oscilloscope |
GPIB, serial, parallel interfaces. HPGL, PCL data formats. |
Hewlett-Packard 54600A Digital Oscilloscope |
No further information. |
Hewlett-Packard 54601A Digital Oscilloscope |
No further information. |
Hewlett-Packard 54603B Digital Oscilloscope |
Serial interface. HPGL, PCL, Epson data formats. |
Hewlett-Packard 54616C Digital Oscilloscope |
Epson, PCL Color data formats. |
Hewlett-Packard 54624A Portable Digital Storage Oscilloscope |
Parallel and serial interfaces.
Epson, PCL data formats. |
Hewlett-Packard 54642D Mixed Signal Oscilloscope |
GPIB interface. Epson data from this unit is 24-pin
head data and requires
PrintCapture 2.9.3 and above. Laserjet and
Deskjet (PCL) data can be processed by PrintCapture
2.9.0, and above, but it creates an image that looks good
visually but doesn't print very well. The LaserJet and
DeskJet images will require the use of an image editor
to produce a printable image. Also be sure to set the
image resolution to about 600 DPI. |
Hewlett-Packard 54645D Mixed Signal Oscilloscope |
GPIB interface. Epson, Laserjet, and Deskjet data
from this unit can now be processed by PrintCapture 3.0.1. |
Hewlett-Packard 70004A Color Display Unit |
HPGL data requires PrintCapture version 2.7.5
or later. Color PrintJet formats cannot be processed by
PrintCapture at this time.
Update: PrintCapture 3.2.3 added support
for Paintjet (PCL color) data processing. |
Hewlett-Packard 70206A Monochrome Display Unit |
HPGL data format requires PrintCapture version
2.7.5 or later. |
Hewlett-Packard 71000 Modular Spectrum Analyzer |
GPIB interface. HPGL data format. |
Hewlett-Packard 87510A Gain-Phase Analyzer |
GPIB interface. HPGL data format. The 87510A sends HPGL "Ox" output
commands that must be processed in real-time. PrintCapture 3.2.17
and later should do a better job of processing the
HPGL "Ox" output commands. See Setup>
Configuration> HPGL Processing> Special
HPGL Command Processing> Process Output Commands. |
Hewlett-Packard 8920B Service Monitor |
Serial interface. PCL data format. |
Hewlett-Packard 89440A Vector Signal Analyzer |
HPGL, PCL data formats. |
Hewlett-Packard 89441A Vector Signal Analyzer |
GPIB interface. HPGL, PCL data formats. |
Hewlett-Packard E4405B Spectrum Analyzer |
Parallel, serial, and GPIB interfaces. |
Hewlett-Packard E5061A ENA-L RF Network Analyzer |
Parallel and GPIB interfaces. |
Hewlett-Packard E5071A ENA Network Analyzer |
Parallel and GPIB interfaces. |
Hewlett-Packard E8358A PNA Network Analyzer |
Parallel, serial, and GPIB interfaces. |
Hitachi VC-6545 |
HPGL data format. There are problems with this 'scope and PrintCapture.
Evidently the VC-6545 inserts carriage-return/line-feeds
into the HPGL data stream that PrintCapture can't
filter out. And there are multiple HPGL scale commands
(IP and/or SC) that PrintCapture can't process yet.
Update: PrintCapture 3.2.24 now processes
multiple scaling commands. |
Humphrey Field Analyzer, Humphrey Filed Analyzer II |
Parallel interface. PCL data format. These eye examination
machines use soft fonts to program Hewlett-Packard LaserJets
for
output. PrintCapture version
3.2.1 is the first version to process soft fonts for the
Humphrey Field Analyzers. You will need a parallel-to-serial
converter to get the data into PrintCapture.
A B&B Electronics
(www.bb-elec.com)
232SPS2 parallel-to-serial converter will work and doesn't
require a parallel-to-Centronics cable. An ATEN
(www.aten.com) SXP-320A will
also work. All ATEN parallel-to-serial
converters (SXP-320A, SXP-325A, SXP-500) are available from
Provantage (www.provantage.com).
The ATEN converters are a little harder to use because
you need to find a DB25M-to-Centronics36F parallel cable
(DB25 Male-to-Centronics36 Female). These cables are a
little harder to find but you might try a search on the
Internet using the keywords "centronics 36F
gender".
Generally speaking, the people that use Humphrey Field Analyzers are not technical people so we provided a color image (573KB) and a black-and-white image (65KB) for them to look at. |
IDEXX Blood Analyzer for Veterinery Medicine (includes VetTest
8008 for blood chemistries and QBC machine for red and white
count) |
Parallel interface. Epson, PCL data formats. |
Innotek SA-7270 Spectrum Analyzer |
Parallel Interface. HP LaserJet PCL. The customer that reported
this device used an ATEN SXP-320A
(www.aten.com). He also reported
that a custom cable was needed where you must disconnect the wire
on pin 36 of the Centronics connector or pin 17 on the DB-25
connector. |
Interak 8-bit Z80 |
Serial interface. HPGL. This customer is using
PrintCapture to document both hardware
and software for this computer. |
Iwatsu SL-4122 Logic Analyzer |
Parallel interface. Epson. |
LeCroy 960 WavePro Oscilloscope |
GPIB, serial, and parallel interfaces. No further
information available. |
LeCroy 9300 Series Oscilloscope |
GPIB, serial, and parallel interfaces. No further
information available. |
LeCroy 9304A Oscilloscope |
GPIB interface. HPGL data format. |
LeCroy 9354AM Digital Oscilloscope |
GPIB interface. HPGL data format. |
LeCroy 9384L Oscilloscope |
GPIB interface. HPGL data format. |
LeCroy 9450A Digital Storage Oscilloscope |
HPGL, PCL, Epson data formats. |
LeCroy LC334A Digital Oscilloscope |
Epson B/W, HPGL, DeskJet Color, DeskJet B/W, LaserJet,
PaintJet, ThinkJet data formats. |
LeCroy LC564D Digital Oscilloscope |
GPIB, serial, and parallel interfaces. Epson B/W, HPGL, DeskJet
Color, DeskJet B/W, LaserJet, TIFF, BMP data formats. |
LeCroy Scope Station 140 |
Epson MX/FX, HP74xx Plotter data formats. |
LG SA-7270 Spectrum Analyzer |
See the information above on the Innotek SA-7270 Spectrum Analyzer. |
Lignext1 SA-7270 Spectrum Analyzer |
See the information above on the Innotek SA-7270 Spectrum Analyzer. |
Lindos Audio Measurement Set |
Serial interface. PCL data format. |
Link Instruments DSO-2102 |
HPGL data format.
Windows 95/98 - HP7470A, HP7475A, HP7550A, HP7580A, HP7580B,
HP7585A, HP7585B, HP7586B
Windows NT/2K - HP7550 Plus, HP-GL/2. |
Marconi 2380 Spectrum Analyzer |
GPIB interface. HPGL data format. The data from the Marconi
2380 is not processed correctly. The text and graphics data
don't line up correctly. The problem is a variation of the multiple
scaling commands that PrintCapture doesn't
process yet.
Update: PrintCapture 3.2.24 now processes
multiple scaling commands. |
Marconi 2382 Spectrum Analyzer |
GPIB interface. HPGL data format. |
Marconi 2945A Communications Service Monitor |
No further information. |
Marconi 6203 Measurement Test Set |
GPIB interface. |
MeasureX Vision Paper Industry Scanner (from Honeywell?) |
Serial interface. Epson data format. |
Mettler Toledo FP81HT-FP90 Thermal Analyzer |
Parallel interface. PCL data format. |
NDC Infrared Enmgineering Coat Weight Profiler NDC8100 |
Serial interface. Epson data format. |
Norsonic RTA 830 Real Time Analyzer |
Unknown, but it may be Epson. |
Ono Sokki CS 350 Dual Channel FFT Analyzer |
GPIB interface. HPGL data format. |
Plisch FMS100 TV Video/Audio Analyzer |
Serial interface. No further information. |
PSpice Software Program |
"The HPGL output of PSice is the best way to capture
very high resolution graphics as a file for word processing." Customer Gregory W. |
Puritan-Bennett Renaissance PFT (Pulmonary Function Test) |
Serial interface. Epson data format. |
Rinco PCS II Ultrasonic Welding Machine |
Serial interface. Unknown output format, but suspect
it is Epson. |
RiserBond 3200 TDR |
Serial interface. Epson data format. |
Rohde Schwarz EMI Test Receiver EASI |
GPIB interface. HPGL data format. |
Rohde Schwarz EMI Test Receiver ESCS30 |
GPIB, parallel interface. HPGL, PCL, Epson data formata. |
Rohde Schwarz EMI Test Receiver ESHS 30 |
GPIB interface. HPGL data format. |
Rohde Schwarz EMI Test System TS9975 |
HPGL data format. |
Rohde Schwarz ESIB. No further information available. |
GPIB interface. HPGL data format. |
Rohde Schwarz ESS. No further information available. |
GPIB interface. HPGL data format. |
Rohde Schwarz FSEM30 Spectrum Analyzer |
GPIB interface. HPGL data format. |
Rohde Schwarz FSH Spectrum Analyzer |
Serial interface. PCL data format. |
Rohde Schwarz Radio Communication Service Monitor CMS32/52 |
Parallel interface. PCL, Epson data formats. Evidently
PCL data gives a little better output. |
Schmid SZ 340 Sound Program Circuit Analyzer |
PCL data format with printer Thinkjet option installed. |
Stanford Research SR770 FFT Network Analyzer |
GPIB interface. HPGL data format. |
Tektronix 370 Curve Tracer |
Parallel interface. HPGL data format. Some customers have
had problems configuring the Tek 370 to work with PrintCapture.
If you're having problems try looking at
this Tek370 & PrintCapture
Setup.pdf document created by one of our customers.
Thank you Gary F. for sharing and Gene N. for verifying
the information!
|
Tektronix 370A Curve Tracer |
GPIB interface. Windows bitmap (BMP) data format. |
Tektronix 370B Curve Tracer |
GPIB interface. Windows bitmap (BMP) data format. |
Tektronix 492P Spectrum Analyzer |
GPIB interface. HPGL data format. |
Tektronix 494AP Spectrum Analyzer |
GPIB interface. HPGL data format. |
Tektronix 494P Spectrum Analyzer |
GPIB interface. HPGL data format. |
Tektronix 495P Spectrum Analyzer |
GPIB interface. HPGL data format. |
Tektronix 496P Spectrum Analyzer |
GPIB interface. HPGL data format. |
Tektronix 497P Spectrum Analyzer |
GPIB interface. HPGL data format. |
Tektronix 571 Curve Tracer |
Parallel interface. Epson data format. |
Tektronix 2021 Arbitrary Waveform Generator |
PCL, Epson data formats. |
Tektronix 2211 Digital / Analog Oscilloscope |
Serial interface. HPGL data format. |
Tektronix 2216 Digital / Analog Oscilloscope |
Option 12, RS-232C communications. HPGL,
Epson, and PCL (LaserJet, Deskjet) data format. |
Tektronix 2232 Digital / Analog Oscilloscope |
HPGL data format. Option 12, RS-232 communications, requires
the parameter switch to be set to 0101000000. Thank you
Mike W.! |
Tektronix 2252 Digital / Analog Oscilloscope |
GPIB and parallel interfaces. Epson data format. |
Tektronix 2430A Digital Storage Oscilloscope |
GPIB interface. HPGL data format. HPGL processing
requires PrintCapture version
3.0.4 or later. There is still a problem processing data
from the 2430A. There is an HPGL "UC" command
that is used to display "user defined characters" like
the "u" used as an abbreviation for microseconds.
This command is not processed yet.
Update: PrintCapture 3.1.0 added support
for HPGL "UC" command processing. |
Tektronix 2710 RF Spectrum Analyzer |
GPIB and parallel interfaces. HPGL data format. |
Tektronix 2710 Spectrum Analyzer for Satelite Tuning |
Parallel interface. HPGL. |
Tektronix 2712 Spectrum Analyzer |
GPIB and serial interfaces. HPGL, Epson data formats. HPGL
processing requires
PrintCapture version 3.0.0 or later. Other
customers have reported using Epson output for PrintCapture
processing. |
Tektronix 2715 Spectrum Analyzer |
GPIB and serial interfaces. HPGL, Epson data formats. HPGL
processing requires
PrintCapture version 3.0.0 or later. Other
customers have reported using Epson output for PrintCapture
processing. |
Tektronix 2754P Spectrum Analyzer |
GPIB interface. |
Tektronix 2755P Spectrum Analyzer |
GPIB interface. |
Tektronix 2756P Spectrum Analyzer |
GPIB interface. |
Tektronix 2782 Spectrum Analyzer |
GPIB interface. |
Tektronix 2794 Spectrum Analyzer |
GPIB interface. |
Tektronix 11801B Digital Sampling Oscilloscope |
GPIB interface. |
Tektronix TDS 210 Digital Real-Time Oscilloscope |
Requires TDS2CMA Communications Extension Module (parallel
port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet,
LaserJet, PCX (PC Paintbrush mono image) data formats. |
Tektronix TDS 220 Digital Real-Time Oscilloscope |
Requires TDS2CMA Communications Extension Module (parallel
port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet,
LaserJet, PCX (PC Paintbrush mono image) data formats. |
Tektronix TDS 224 Digital Real-Time Oscilloscope |
Requires TDS2CMA Communications Extension Module (parallel
port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet,
LaserJet, PCX (PC Paintbrush mono image) data formats. |
Tektronix TDS 320 Digital Real-Time Oscilloscope |
Serial, parallel, and GPIB output ports. BMP, Epson, Thinkjet,
Deskjet, Laserjet, PCX (PC Paintbrush mono image), TIFF
(Tagged Image File Format) data formats. |
Tektronix TDS 360 Digital Real-Time Oscilloscope |
Serial, parallel, and GPIB output ports. BMP, Epson, Thinkjet,
Deskjet, Laserjet, PCX (PC Paintbrush mono image), TIFF
(Tagged Image File Format) data formats. |
Tektronix TDS 380 Digital Real-Time Oscilloscope |
Serial, parallel, and GPIB output ports. BMP, Epson, Thinkjet,
Deskjet, Laserjet, PCX (PC Paintbrush mono image), TIFF
(Tagged Image File Format) data formats. |
Tektronix TDS 420A Digitizing Oscilloscope |
Has a GPIB interface and optional parallel and serial interfaces. BMP,
Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX
(PC PaintBrush mono image), TIFF (Tagged Image File
Format) data formats. |
Tektronix TDS 430A Digitizing Oscilloscope |
Has a GPIB interface and optional parallel and serial interfaces.BMP,
Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX
(PC PaintBrush mono image), TIFF (Tagged Image File
Format) data formats. |
Tektronix TDS 460 Digitizing Oscilloscope |
Has a GPIB interface and optional parallel and serial interfaces.
BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet,
PCX
(PC PaintBrush mono image), TIFF (Tagged Image File
Format) data formats. |
Tektronix TDS 460A Digitizing Oscilloscope |
Has a GPIB interface and optional parallel and serial interfaces.
BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet,
PCX
(PC PaintBrush mono image), TIFF (Tagged Image File
Format) data formats. |
Tektronix TDS 540A Digitizing Oscilloscope |
BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet,
PCX (PC PaintBrush mono image), TIFF (Tagged Image File
Format) data formats. |
Tektronix TDS 540B Digitizing Oscilloscope |
BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet,
PCX (PC PaintBrush mono image), TIFF (Tagged Image File
Format) data formats. |
Tektronix TDS 640A Digitizing Oscilloscope |
BMP, Epson, HPGL Color Plot, ThinkJet, DeskJet, LaserJet,
PCX (PC PaintBrush mono image), TIFF (Tagged Image File
Format) data formats. |
Tektronix TDS 694C Digital Storage Oscilloscope |
GPIB, serial, and parallel interfaces. BMP, Epson,
HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX
(PC PaintBrush mono image), TIFF (Tagged Image File
Format) data formats. |
Tektronix TDS 754A Digitizing Oscilloscope |
GPIB interface. BMP, Epson, HPGL Color Plot, ThinkJet,
DeskJet, LaserJet, PCX (PC PaintBrush mono image), TIFF
(Tagged Image File Format) data formats. |
Tektronix TDS 754D Digitizing Oscilloscope |
GPIB, serial, and parallel interfaces. BMP, Epson,
HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush
mono image), TIFF (Tagged Image File Format) data formats. |
Tektronix TDS 784A Digital Phosphor Oscilloscope |
GPIB, serial, and parallel interfaces. BMP, Epson,
HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush
mono image), TIFF (Tagged Image File Format) data formats. |
Tektronix TDS 784D Digital Phosphor Oscilloscope |
GPIB, serial, and parallel interfaces. BMP, Epson,
HPGL Color Plot, ThinkJet, DeskJet, LaserJet, PCX (PC PaintBrush
mono image), TIFF (Tagged Image File Format) data formats. |
Tektronix TDS 1002 Digitizing Oscilloscope |
Requires TDS2CMAX Communications Extension Module (parallel
port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet,
LaserJet, PCX (PC Paintbrush mono image), TIFF (Tagged Image
File Format) data formats. |
Tektronix TDS 2012 Digitizing Oscilloscope |
Requires TDS2CMAX Communications Extension Module (parallel
port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet,
LaserJet, PCX (PC Paintbrush mono image), TIFF (Tagged Image
File Format) data formats. |
Tektronix TDS 2014 Digitizing Oscilloscope |
Requires TDS2CMAX Communications Extension Module (parallel
port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet,
LaserJet, PCX (PC Paintbrush mono image), TIFF (Tagged Image
File Format) data formats. |
Tektronix TDS 2022 Digitizing Oscilloscope |
Requires TDS2CMAX Communications Extension Module (parallel
port, serial port, GPIB). BMP, Epson, ThinkJet, DeskJet,
LaserJet, PCX (PC Paintbrush mono image), TIFF (Tagged Image
File Format) data formats. |
Tektronix TDS 3034B Digital Phosphor Oscilloscope |
Includes parallel port interface standard. Requires TDS3GV
Communications Extension Module for serial port and GPIB
interfaces. BMP, Epson, ThinkJet,
DeskJet, LaserJet, PCX (PC Paintbrush mono image), TIFF
(Tagged Image File Format), HPGL data formats. |
Tektronix TDS 3052 Digital Phosphor Oscilloscope |
Includes parallel port interface standard. Requires TDS3GM
Communications Extension Module for serial port and GPIB
interfaces. BMP, Epson, ThinkJet,
DeskJet, LaserJet, PCX (PC Paintbrush mono image), TIFF
(Tagged Image File Format), HPGL data formats. |
Tektronix THS 720P Battery-Powered Oscilloscope |
No further information. |
Tektronix TS 100 TelScout |
Serial interface. Epson data format. |
Tektronix VM700 Video Test Set |
Serial interface. PCL data format. |
Tektronix VM700A Video Test Set |
Serial interface. PCL data format. |
Tencor P-1 Longscan Profilometer |
Serial interface. PCL data format. |
Toshiba Injection Molding Machines with V10 and V21 controllers |
Serial interface. Epson data format. |
VolTech TF2000 Gain/Phase and Harmonic Analyzer |
Serial and parallel interfaces. Epson data format. |
Wallac Wizard 1480 Gamma Counter |
Serial interface. Epson and PCL3 data formats. |
Wandel & Goltermann PCM4 PCM Channel
Measuring Set |
GPIB interface. HPGL data format. |
Wandel & Goltermann SNA-1 Network/Spectrum Analyzer |
GPIB interface. HPGL data format. Needs GPIB address set
to receive on GPIB address 29. HPGL plot needs to be scaled
to 500-700. |
Yokogawa DL708E Digital Oscilloscope and Recorder |
GPIB, serial, and parallel interfaces. BMP,
Epson, HPGL, PCL, TIFF (Tagged Image File Format) data formats. |
Yokogawa DL1540CL Portable Digital Oscilloscope |
GPIB interface. BMP, Epson, HPGL Color Plot, PCL,
TIFF (Tagged Image File Format) data formats. |